Carlton Siva S-24

 

Home Main Database Database CanadaPhotos Carlton Siva S-24

 

DATASHEET OXYGEN REBREATHER

 SIVA S-24

Date: 13 June 2003

 Multi role shallow water MCM diving

JW. Bech

Manufacturer

Carleton

 

Model

Siva S-24

CC and SCR

Land of origin

Canada

 

Special Note: 

Mine Counter Measure

 

User group

Military

 

Part no:

 S-24

 

Working principle

Automatic counterlung demand valve and inline mass flow control

valve adjusted pre-dive to suit the gas mixture that is employed.

or fixed mass flow - no demand valve.

 

Gas type

Pure oxygen 0-8 mtrs

Ntrox 0-24 mtrs

Cylinder volume

1.5 or 2.2 litre bottle Oxygen

Supplemantary nitrox bottle

Max. cylinder pressure

200 bar

 

Material of cylinder

?

 

Counterlung inspire

?

 

Counterlung exhale

 

 

Dive time duration

Max 4 hours depending on bottle

 

Operating temperature

 

 

Magnetic signature

Fully non-magnetic

Acoustically safe

Weight ready to use in Air

<14 kg

 

Weight ready to use in water

neutral

 

MOD

55 mtr with adapted nitrox mix

 

Scrubber material

protosorb

4 hr duration at 0 gr C

Colour

Black

 

Dimensions

LWD 430x320x200 mm

 

Worn

Chest mounted

 

Mouthpiece

 

 

Backpack

 

 

Extra

 

 

Extra

 

 

 

 

 

 

 

 

If you have any information to add this sheet please mail it to jw.bech@quicknet.nl References to source and names will always be added!  

 

Info found:

 

Origin: http://www.therebreathersite.nl

 

Info: http://www.carltech.com/diving/SIVA24.pdf

 

 Accessories and Optional Equipment

  • Calibration instruments.
  • Low Magnetic tool kit.
  • High Impact transit case.
  • Maintenance spares kit.
  • 1.5 or 2.2 litre flask.
  • Supplementary gas flask assembly for extended semi-closed operations.
  • Buoyancy compensator (supports diver in head-up position on surface when fully
  • inflated).

 

 

 