DATASHEET OXYGEN REBREATHER
|
OXYGERS 1957
|
Date: 9 Februari 2003 |
La Spirotechnique –GERS-Fenzy
|
JW. Bech
|
Manufacturer |
Spirotechnique / GERS/ Fenzy |
OPS/Aqualung |
Model
|
Oxygers 1957 |
.prototype 57-97 model |
Land of
origin |
France |
|
Special
Note: |
CCR
|
|
User
group |
Military |
|
Part
no: |
1.5L
cylinder ? |
|
Working principle |
On
demand principle |
(regulator fixed on lung) |
Gas type |
Oxygen |
|
Cylinder volume |
1.5 L |
|
Max. cylinder pressure
|
200 bar |
|
Material of cylinder
|
Steel
(?) |
|
Counterlung inspire |
5 L |
|
Counterlung exhale |
- |
|
Dive time duration |
3 hours |
|
Operating temperature
|
|
|
Magnetic signature |
- |
|
Weight ready to use in Air
|
? |
|
Weight ready to use in water
|
? |
|
MOD |
7 mtrs
|
|
Scrubber material |
Soda
Lime 1,7kgs 2 L |
|
Colour |
Black
/Brown |
|
Price |
? |
|
Worn |
Chest |
|
Mouthpiece |
Dual
hose with switch-off valve |
Neckstrap |
External pack |
Hard
shell outer casing |
|
Dimension |
|
|
Extra |
|
|
|
Original design by Perimond
Trouchet & L.V. Alinat. |
|
|
|
|
If you
have any information to add this sheet please mail it to
jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info found: Brochure la
Spirotechnique in my archive ;) |
|
Origin:
http://www.therebreathersite.nl |
|
|
|
|
|