Oxygers 57/97

 

home Main Database Database FrancePage up Photos Oxygers 57/97

 

DATASHEET OXYGEN REBREATHER

 OXYGERS 57/97

Date: 9 Februari 2003

La Spirotechnique –OPS-Aqualung 

JW. Bech

Manufacturer

Aqualung / Spirotechnique

OPS

Model

Oxygers 57/97

.

Land of origin

France

 

Special Note: 

CCR

 

User group

Military

 

Part no:

 444555 with 1.5L cylinder

444554 with 2 L cylinder

Working principle

On demand principle

(regulator fixed on lung)

Gas type

Oxygen

 

Cylinder volume

1.5 L or 2.0 L

 

Max. cylinder pressure

200 bar

 

Material of cylinder

Aluminium Alloy AL 6061 (?)

 

Counterlung inspire

5 L

 

Counterlung exhale

-

 

Dive time duration

3 hours

 

Operating temperature

 

 

Magnetic signature

Non-magnetic

 

Weight ready to use in Air

9,7 kgs

 

Weight ready to use in water

neutral

 

MOD

7 mtrs

 

Scrubber material

Soda Lime 1,7kgs 2 L

 

Colour

Black /Brown

 

Price

?

 

Worn

Chest

 

Mouthpiece

Dual hose with switch-off valve

Neckstrap

External pack

Hard shell outer casing

 

Dimension

WxTxH 340x170x340mm

 

Extra

 

 

 

 

 

 

 

 

If you have any information to add this sheet please mail it to jw.bech@quicknet.nl References to source and names will always be added!  

 

Info found: Brochure la Spirotechnique in my archive ;)

 

Origin: http://www.therebreathersite.nl

 

 

 

Operating principle:
The Oxygers 57/97 is a closed circuit diving set using pure oxygen. It operates on the “demand” principle. It consists of a front-mounted rigid outer shell enclosing the absorbent cartridge, the oxygen cylinder, and the counterlung. Oxygen is automatically replaced as it is consumed. The circulation of gas is ensured by a set of two valves.
Special Features:
The apparatus is Non Magnetic (to NATO standards). No special tools are required for its regular maintenance.
Operational use:
The apparatus offers discrete dives of long duration and is used on sensitive military dives

 

 

 
 

Top of Page