DATASHEET OXYGEN REBREATHER

Draegerolith

Date: 30 November 2009

 

Database oxygen rebreathers by: J.W. Bech

Manufacturer

Draeger Werk

 

Model

Draegerolith

 

Land of origin

Germany

 

Special Note: 

Liquid oxygen

 

User group

Minerescue

 

Part no:

-

 

Working principle

Evaporation of liquid oxygen

 

Gas type

Pure oxygen

 

Cylinder volume

4,75  ltr ;iquid oxygen

 

Max. cylinder pressure

-

 

Material of cylinder

-

 

Counterlung inspire volume

-

 

Counterlung exhale volume

-

 

Dive time duration

3-4 hours

 

Operating temperature

-

 

Magnetic signature

-

 

Weight ready to use in Air

12 kg

 

Weight ready to use in water

-

 

MOD

-

 

Scrubber material

No scrubber

 

Colour

-

 

Price

-

 

Worn

Back

 

Mouthpiece shut off valve

y

 

Full Face mask attached (FFM)

n

 

Backpack

y

 

Extra info:

 

 

Extra info:

 

Additional information:

 

Email address owner

 

 

 

 

If you have any information to add this sheet please mail it to jw.bech@quicknet.nl References to source and names will always be added!  

 

Info found: J. Gompelman

 

Origin: http://www.therebreathersite.nl

 

Info:

 

 

 

 

November 2009
 
Please sign my Guestbook
Email: jw.bech@quicknet.nl

 

 

This is the datasheet of the Draegerolith liquid oxygen breathing apparatus. Not a true rebreather but it was used for lifesaving in the mines in Germany in the 1920's


Menu German Oxygen rebreathers

Updates

Speedmenu

Search page

Webshop

Home

Photos Draegerolith


Therebreathersite:
Mainmenu:

 
Search this Website
 Information about RB
 Photo galleries
 Historical Information
 Links & Downloads
 Reviews
 Homebuilders
 Electronics
 Updates, speed menu
 Web shop
 Reviews SC rebreathers
 Reviews CC rebreathers
 RB’s through the ages
 Inspiration rebreather
 Database Oxygen RB’s
 Database Semiclosed RB’s
 Updates
 Speed menu
 Search this web