DATASHEET OXYGEN REBREATHER
|
Dräger BG174
|
Date:
21 July 2002
|
|
JW. Bech
|
Manufacturer
|
Dräger
|
|
Model
|
BG
174-A
|
|
Land of origin
|
Germany
|
|
Special Note:
|
Minerescue/ Fire pers.
|
|
User group
|
Rescue teams
|
|
Part no:
|
|
|
Working
principle
|
Closed Circuit
|
|
Gas
type
|
Pure
oxygen
|
99,5
Vol % O2
|
Cylinder
volume
|
2 liter
|
|
Max.
cylinder pressure
|
200 bar
|
|
Material
of cylinder
|
Alloy (CrMo) steel
|
|
Counterlung
inspire
|
6 ltrs
|
|
Counterlung
exhale
|
-
|
|
Dive
time duration
|
~ 4 hours
|
|
Operating
temperature
|
|
|
Magnetic
signature
|
|
|
Weight
ready to use in Air
|
12.8 kgs
(updated)
|
|
Weight
ready to use in water
|
|
|
MOD
|
|
|
Scrubber
material
|
Sodasorb
|
|
Colour
|
Black
|
|
Price
|
|
|
Worn
|
on the Back
|
|
Mouthpiece
|
With strap
|
Open/Close by lever
|
Backpack
|
No
|
|
Extra
|
Auto Addition
|
|
The BG174 is equipped with a warning device. The warning signal flaps are
normally not activated when the counterlung is filled. The moment the
counterlung is empty, the unit will produce a ‘musical, tone pneumatical
generated by a valve.
|
|
|
|
If
you have any information to add this sheet please mail it to jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info
found:
|
|
Origin:
http://www.therebreathersite.nl
|
|
Info:
http://www.dep.state.pa.us/dep/deputate/minres/dms/website/rescue/manual/section8.htm
|
|
http://www.labour.gov.sk.ca/safety/mine-rescue-manual/chapter-2/breathing-apparatus.htm
link thanks to Karl
|
|
Added 15 september 2004:
intermediate pressure from the valve group
regulator forces( via a small air line and piston) the acoustic reed
warning device away from the inhalation side of the breathing bag. When
there is no cylinder pressure, or the cylinder is turned off e.g an
entrapment procedure, the flap with the acoustic reeds closes over the
inhalation valve and thus lets the user know their situation.
Contribution of: Kirsten Swinton (Aus)
|
|
|
|
|
|
|
|