DATASHEET ‘OXYGEN’ REBREATHER
|
Dräger Tauchretter 1913 (mixing
model)
|
Date: 03 December 2002 |
|
JW. Bech
|
Manufacturer |
Dräger |
|
Model
|
Tauchretter with diluent |
|
Land of
origin |
Germany |
|
Special
Note: |
Kapok
coated Jacket |
|
User
group |
Military Submarine escape |
|
Part
no: |
- |
|
Working principle |
Constant Mass flow |
Pressure reducer and doses unit first applied |
Gas type |
Oxygen
/ Compressed Air |
|
Cylinder volume |
2 x 2
ltr |
|
Max. cylinder pressure
|
150 bar
|
|
Material of cylinder
|
Steel |
|
Counterlung inspire |
Worn on
the back |
|
Counterlung exhale |
Non |
|
Dive time duration |
|
|
Operating temperature
|
|
|
Magnetic signature |
|
|
Weight ready to use in Air
|
|
|
Weight ready to use in water
|
|
|
MOD |
|
|
Scrubber material |
Alkali
cartridge |
Isolated Scrubber cartridge and valves |
Colour |
|
|
Price |
|
|
Worn |
Counterlung on the back |
|
Mouthpiece |
Double
hose with valves |
|
Backpack |
|
|
Extra |
|
|
Extra |
|
|
|
|
|
The 1913 model differs in
scrubber construction counter model 1912. The 1913 model was a oxygen/diluent
rebreather with isolated scrubber and valve. The isolation was airtight
so that several connections could be simplified. This model was patented
D.R.P 271829 and D.R.P 285928. If you have acces to these patents please
sent me a copy!! |
|
|
If you
have any information to add this sheet please mail it to
jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info found: |
|
Origin:
http://www.therebreathersite.nl |
|
Info:
|
|
|
|