DATASHEET OXYGEN REBREATHER
|
Dräger Travox 120
|
Date: 13 June 2003 |
Not for underwater use
|
JW. Bech
|
Manufacturer |
Dräger |
70’s |
Model
|
Travox 120 |
|
Land of
origin |
Germany |
|
Special
Note: |
Predecessor of the BG4 |
|
User
group |
Fire
fighters |
|
Part
no: |
|
|
Working principle
|
CMF |
|
Gas type |
100%
oxygen |
|
Cylinder volume
|
1
litres |
|
Max. cylinder pressure
|
200 bar |
|
Material of cylinder
|
steel |
|
Counterlung inspire
|
5 liter |
|
Counterlung exhale
|
- |
|
Dive time duration
|
90 min – 30 min
spare (2h) |
|
Operating temperature
|
-15
degr C + 40 gr. C |
|
Magnetic signature
|
- |
|
Weight ready to use in Air
|
10,9 kg |
|
Weight ready to use in water
|
- |
|
MOD |
- |
|
Scrubber material
|
2,2
ltrs |
|
Colour |
Green/orange |
|
Price |
? |
|
Worn |
On the
back |
|
Mouthpiece |
Dual
hose “seitenschlauch” |
|
Backpack |
aluminium |
|
Extra |
|
|
Extra |
|
|
|
|
|
|
|
If you
have any information to add this sheet please mail it to
jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info found: |
|
Origin:
http://www.therebreathersite.nl |
|
Info:
|
|
The FFM is equipped with
screen whiper. IP = 4 bar before restriction. Build in warningsignal at
low pressure. Still in use, but will be replaced by the BG 4 and the
Tramix |
|