DATASHEET OXYGEN REBREATHER
|
Dräger Tubben
|
Date: 18 Oktober 2006 |
|
Database oxygen rebreathers by:
J.W. Bech
|
Manufacturer |
Dräger |
|
Model |
Tübben |
|
Land of origin |
Germany |
|
Special Note: |
Developed 1 year before WWI by Dräger |
1913 |
User group |
Gasschutz |
|
Part no: |
|
|
Working principle
|
Manual |
|
Gas type |
Pure oxygen |
|
Cylinder volume |
|
|
Max. cylinder pressure
|
150
bar |
|
Material of cylinder
|
steel |
|
Counterlung inspire volume |
Pendulem system |
|
Counterlung exhale volume |
n.a |
|
Dive time duration
|
Not
for UW use |
|
Operating temperature
|
- |
|
Magnetic signature
|
- |
|
Weight ready to use in Air
|
- |
|
Weight ready to use in water
|
- |
|
MOD |
Not
for UW use |
|
Scrubber material
|
|
|
Colour |
|
|
Price |
|
|
Worn |
Chest |
|
Mouthpiece shut off valve |
No |
|
Full Face mask attached (FFM) |
No |
Noseclamp |
Backpack |
No |
|
Extra info: |
Used in WW I |
|
Extra info: |
|
Additional information: |
|
Email address owner |
|
|
|
|
If
you have any information to add this sheet please mail it to
jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info found: Manuskriptdruck
1934 |
|
Origin:
http://www.therebreathersite.nl |
|
Info: jw.bech(AT)Therebreathersite.nl |
|
This unit was used for the
design of “das Heeres-Sauerstoff-Schutz- Gerät Modell 1916 (HSS
gerät). The Dräger Tubben unit was based on the injector type
principle. This HSS gerät was based on the “lungoperated” principle.
The HSS unit had valves that were operated by lung power (sucksion)
|