DATASHEET OXYGEN REBREATHER
|
MSA M20 chemical rebreather
|
Date: 04 January 2004 |
|
Database oxygen rebreathers by:
J.W. Bech
|
Manufacturer |
MSA |
|
Model
|
M20 |
|
Land of
origin |
USA |
|
Special
Note: |
Chemical
rebreather |
|
User
group |
Military |
|
Part
no: |
NSN
4240-00-678-5263 |
|
Working principle |
Chemical oxygen generation |
|
Gas type |
Pure
oxygen |
|
Cylinder volume |
No
cylinder |
|
Max. cylinder pressure
|
- |
|
Material of cylinder
|
- |
|
Counterlung inspire volume |
unknown |
|
Counterlung exhale volume |
unknown |
|
Dive time duration |
Max 60
min/ advised 45 min |
|
Operating temperature
|
Standard canister >50 degr F |
Selfstarting canister <50 degr F |
Magnetic signature |
- |
|
Weight ready to use in Air
|
17 ¾ LB
with canister |
|
Weight ready to use in water
|
Not for
UW use |
|
MOD |
- |
|
Scrubber material |
superoxides |
|
Colour |
|
|
Price |
|
|
Worn |
On the
Back |
|
Mouthpiece shut off valve |
n |
|
Backpack |
n |
|
Extra |
|
|
Extra |
|
Additional information: |
The unit
can be used with the standard canister (grey) to be used at temperatures
above 50F. if the user uses a green canister that is self starting the
rebreather can be used at temperatures under 50F. |
Email address owner |
|
|
|
|
If you
have any information to add this sheet please mail it to
jw.bech@quicknet.nl
References to source and names will always be added!
|
|
Info found: |
|
Origin:
http://www.therebreathersite.nl |
|
Info:
|
|
Information supplied by
Johannes Möller,
thanks !
Check his great site here:
http://gasmasklexikon.com/ |
|